AB-U2T-A030B-SX 30KW/40KW ACDC Air Cooling Power Module for DC Charger Class B CE/UKCA/CSA/UL




Product Introduction
Shanghai Mida EV Power Co.,Ltd. has launched the new AB-U2T-A030B-SX 30kW/40kW smart charging module, which is specially designed for new energy vehicle charging infrastructure. As a national high-tech enterprise with eight years of experience in the research and development of new energy charging equipment, we have perfectly combined industrial-grade protection with intelligent control with 12 core patented technologies. The module supports 150-1000V ultra-wide DC output, three-phase 260-530V AC input, peak efficiency of 97.5%, and still maintains 97.2% high efficiency under 400V input/800V output conditions. The glue filling process creates an IP68-level protection core, which can operate stably in extreme environments of -40℃ to 75℃. It is specially equipped with an intelligent temperature control system, and automatically linearly derates above 55℃ to ensure equipment safety. Multi-module parallel control is achieved through the CAN bus, supporting 12 safety protections such as overvoltage, overcurrent, and overtemperature. With the self-developed operation and maintenance management system, the module status can be monitored in real time. We promise to provide an extended three-year warranty, and a 24/7 technical support team to ensure that charging stations operate all year round. With military-grade quality and highly competitive prices, we help customers quickly deploy smart charging networks.
Features
High-efficiency power conversion
● 97.5% peak conversion efficiency leads the industry
● Three-phase 0.99 ultra-high power factor
● <5% input current harmonic distortion
● Standby power consumption less than 10W energy-saving design
Intelligent power management system
● CAN2.0B communication protocol supports multi-machine parallel connection
● 0.5-100A unlimited current limit regulation
● ±1% output voltage accuracy control
● Automatically identify high and low voltage modes and intelligently switch

Military-grade protection system
● Glue filling process achieves internal IP68 protection level
● Stable operation in a wide temperature range of -40℃ to 75℃
● 55℃ intelligent temperature control derating protection mechanism
● Passed 10kV withstand voltage test and salt spray test certification
Modular operation and maintenance solution
● Front maintenance design for quick replacement in 5 minutes
● 212CFM independent air duct cooling system
● LED three-color indicator for fault self-diagnosis
● Support hot-swap to reduce operation and maintenance costs

Application
● Highway super charging station
Meet the ultra-fast energy replenishment needs of 800V high-voltage platform models, modular design supports multiple machines in parallel to achieve 480kW charging stacks, and adapts to outdoor environments with large temperature differences between day and night.
● Urban bus charging hub
Precise constant current and constant voltage output matches different SOC batteries, IP54 protection level effectively resists parking lot dust, and supports intelligent power allocation during peak and valley electricity price periods.
● Cold chain logistics charging park
-40℃ low temperature self-starting characteristics ensure the normal operation of refrigerated fleets in winter, and the glue-filled sealing structure prevents condensation water erosion, which is suitable for high humidity environments around cold storage.
● Industrial park photovoltaic storage and charging project
530V wide voltage input is compatible with photovoltaic fluctuations, and is equipped with energy storage system to achieve 100% green electricity charging, and CAN communication interface seamlessly connects to energy management system.
Structure
Parameter
|
Parameter |
Description/condition |
Min |
Nor |
max |
Unit |
|
AC input side parameters |
|||||
|
Input voltage three |
Line to line voltage |
260 |
400 |
530 |
Vac |
|
phase |
|||||
|
Input current |
@ input L-L 320Vacfullload |
|
|
60 |
A |
|
Line frequency |
|
47 |
50/60 |
63 |
Hz |
|
Leakage current |
@Vin=400Vac |
|
|
3.5 |
mA |
|
Power factor |
Fullload |
0.99 |
|
|
|
|
THD |
Full load |
|
|
5% |
|
|
Efficiency |
Max.Value@ 800Vdc half load |
|
97.4 |
|
% |
|
|
Max. vaule@ 800Vdc fullload |
|
97.20% |
|
% |
|
DC output side parameters |
|||||
|
Output voltage |
|
150 |
1000 |
1000 |
Vdc |
|
Output current |
Max. value, @Vout=300Vand Pout=30KW |
|
|
100 |
A |
|
Output power |
Vin=320~530Vac, Vout=300~1000Vdc |
|
30 |
30 |
KW |
|
Startup current |
% of current at normal operation |
|
|
110 |
% |
|
Parameter |
Description/condition |
Min |
Nor |
max |
Unit |
|
AC side parameters |
|||||
|
AC voltage accuracy |
Measurement @ Nominal voltage 400Vac |
|
|
+/-2V |
Vac |
|
|
|
|
|
|
|
|
DC output side parameters |
|||||
|
DC output voltage |
measurement accuracy @ 150~1000Vdc range |
|
|
+/-0.5% |
|
|
Setting definition |
0.5 |
|
|
V |
|
|
DC output current |
Measurement accuracy |
|
|
1 |
A |
|
Current setting definition |
0.1 |
|
|
A |
|
|
Ambient temperature |
Measurement accuracy |
|
|
+/-3 |
°C |
Quality Control
Packaging
description2

Floor Mounted DC Charging Station
Split DC Charging Sattion
Mobile DC Charging Station
Energy Storage+Charging
DC-DC Air-cooled Charging Module